TABLE III. Group A inspection for device type 06 - Continued.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
CLR |
J |
K |
A |
B |
C |
D |
GND |
SL |
CLK |
QD |
QD |
QC |
QB |
QA |
VCC |
Min |
Max |
Unit |
||||
10 TC = 125°C " " " " " " " " " " " |
fMAX |
(Fig 9) |
111 |
B |
5.0 V |
GND |
GND |
5.0 V |
IN |
OUT |
5.0 V |
QA |
12 |
MHz |
|||||||||
tPHL1 " " " |
3003 (Fig 9) " " |
112 113 114 115 |
IN " " " |
5.0 V " " " |
5.0 V " " " |
5.0 V " " " |
5.0 V " " " |
GND " " " |
GND " " " |
" " " " |
OUT |
OUT |
OUT |
OUT |
" " " " |
CLR to QA CLR to QB CLR to QC CLR to QD |
7 " " " |
34 " " " |
ns " " " |
||||
tPHL2 " " " |
" " " " |
116 117 118 119 |
B " " " |
IN |
IN |
IN |
IN |
" " " " |
IN " " " |
" " " " |
OUT |
OUT |
OUT |
OUT |
" " " " |
CLK to QA CLK to QB CLK to QC CLK to QD |
" " " " |
28 " " " |
" " " " |
||||
tPHL2 " " " |
" " " " |
120 121 122 123 |
" " " " |
IN |
IN |
IN |
IN |
" " " " |
" " " " |
" " " " |
OUT |
OUT |
OUT |
OUT |
" " " " |
CLK to QA CLK to QB CLK to QC CLK to QD |
" " " " |
34 " " " |
" " " " |
||||
2 |
Same tests, terminal conditions, and limits as subgroup 10 except TC = -55°C. |
11 A = normal clock pulse, except for subgroup 7 and 8 (see 31).
21 B = momentary GND, then VIN except for subgroups 7 and 8. For subgroups 1, 2 and 3, VIN = VCC; for subgroups 9, 10 and 11, VIN = 3.0 V minimum (see figure 11).
31 For subgroups 7 and 8, A = VCC and B = GND.
41 Output voltages shall be either:
(a) H = 2.4 V minimum and L = 0.4 V maximum when using a high speed checker double comparator, or
(b) H � 1.5 V and L < 1.5 V when using a high speed checker single comparator.
51 The tests in subgroups 7 and 8 shall be performed in the sequence specified.
61 Only a summary of attributes data is required.
71 For device type 06, schematic circuits A and B, the minimum and maximum limits shall be -0.4 and -1.3 mA, respectively. For schematic C, the minimum and maximum limits shall be -0.7 and -1.6 mA, respectively.