TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A, B, C, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Min |
Max |
Unit |
|||||||||||||||||||
Test No. |
SIA |
SIB |
QA |
QB |
QC |
QD |
GND |
CLK |
CLR |
QE |
QF |
QG |
QH |
VCC |
|||||||
7 TC = 25°C 31 61 " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
Truth table test 51 " " " " " " " " " " " " " " " " " " " " " " " " " " " |
3014 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 |
B " " " " " " " " " " " " A " " " " " " " " " " " " " " " " " |
B " " " " " " " " " " " " A " " " " " " " " " " " " " " " " " |
L " " " " " " " " " " " " " " H " " " " " " " " " " " " " " L |
L " " " " " " " " " " " " " " " " H " " " " " " " " " " " " L |
H H L " " " " " " " " " " " " " " " " H " " " " " " " " " " L |
H " " " L " " " " " " " " " " " " " " " " H " " " " " " " " L |
GND " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
A B A B A B A B A B A B A A B A B A B A B A B A B A B A B A A |
A " " " " " " " " " " " " " " " " " " " " " " " " " " " " " B |
H " " " " " L " " " " " " " " " " " " " " " " H " " " " " " L |
H " " " " " " " L " " " " " " " " " " " " " " " " H " " " " L |
H " " " " " " " " " L " " " " " " " " " " " " " " " " H " " L |
H " " " " " " " " " " " L " " " " " " " " " " " " " " " " H L |
4.5 V " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
41 |
|||
8 |
Repeat subgroup 7 at TC = +125° C and TC = -55° C. |
See footnotes at end of device type 03.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business