TABLE lll. Group A inspection for device type 06.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Subgroup |
Symbol |
MlL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
CLR |
J |
K |
A |
B |
C |
D |
GND |
SL |
CLK |
Q D |
QD |
QC |
QB |
QA |
VCC |
Min |
Max |
Unit |
||||
1 TC = 25°C " " " " " ’‘ " " " " " " " " " " " " " " " " " " " " |
VOH " " " " |
3006 " " " " |
1 2 3 4 5 |
2.0 V " " " " |
2.0 V " " " 0.8 V |
2.0 V " " " 0.8 V |
2.0 V " " " 0.8 V |
2.0 V " " " 0.8 V |
GND " " " " |
0.8 V " " " " |
A 1/ " " " " |
-0.8 mA |
-0.8 mA |
-0.8 mA |
-0.8 mA |
-0.8 mA |
4.5 V " " " " |
QA QB QC QD Q D |
2.4 " " " " |
V " " " " |
|||
VOL " " " " |
3007 " " " " |
6 7 8 9 10 |
" " " " " |
" " " " 2.0 V |
" " " " 2.0 V |
" " " " 2.0 V |
" " " " 2.0 V |
" " " " " |
" " " " " |
" " " " " |
16 mA |
16 mA |
16 mA |
16 mA |
16 mA |
" " " " " |
QA QB QC QD Q D |
0.4 " " " " |
" " " " " |
||||
VlC " " " " " " " " |
11 12 13 14 15 16 17 18 19 |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
" " " " " " " " " |
-12 mA |
-12 mA |
" " " " " " " " " |
CLR J K A B C D SL CLK |
-1.5 " " " " " " " " |
" " " " " " " " " |
||||||||
llL1 |
3009 |
20 |
0.4 V |
" |
5.5 V |
5.5 V |
CLR |
-0.4 |
-1.3 |
mA |
|||||||||||||
llL2 " " " " " " |
" " " " " " " |
21 22 23 24 25 26 27 |
GND B 2/ |
0.4 V 5.5 V |
0.4 V |
5.5 V 0.4 V |
0.4 V |
0.4 V |
0.4 V |
" " " " " " " |
5.5 V 5.5 V GND " " " 0.4 V |
A |
" " " " " " " |
J K A B C D SL |
7/ |
||||||||
llL3 |
" |
28 |
5.5 V |
" |
0.4 V |
" |
CLK |
-0.7 |
-1.6 |
mA |
See footnotes at end of device type 06.