TABLE III. Group A inspection for device type 03.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A, B, C, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Min |
Max |
Unit |
|||||||||||||||||||
Test No. |
SIA |
SIB |
QA |
QB |
QC |
QD |
GND |
CLK |
CLR |
QE |
QF |
QG |
QH |
VCC |
|||||||
1 TC = 25°C " " " " " ’‘ " " " " " " " " " " " " " " " " " " " " " " " " |
VOH " " " " " " " |
3006 " " " " " " " |
1 2 3 4 5 6 7 8 |
2.0 V " " " " " " " |
2.0 V " " " " " " " |
-0.4 mA |
-0.4mA |
-0.4 mA |
-0.4 mA |
GND " " " " " " " |
A 1/ " " " " " " " |
4.5 V " " " " " " " |
-0.4 mA |
-0.4 mA |
-0.4 mA |
-0.4 mA |
4.5 V " " " " " " " |
QA QB QC QD QE QF QG QH |
2.4 " " " " " " " |
V " " " " " " " |
|
VOL " " " " " " " |
3007 " " " " " " " |
9 10 11 12 13 14 15 16 |
0.8 V " " " " " " " |
0.8 V " " " " " " " |
8 mA |
8 mA |
8 mA |
8 mA |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
8 mA |
8 mA |
8 mA |
8 mA |
" " " " " " " " |
QA QB QC QD QE QF QG QH |
0.4 " " " " " " " |
" " " " " " " " |
||
VIC " " " |
17 18 19 20 |
-12 mA |
-12 mA |
" " " " |
-12 mA |
-12 mA |
" " " " |
SIA SIB CLK CLR |
-1.5 " " " |
" " " " |
|||||||||||
IIL1 " " |
3009 " " |
21 22 23 |
0.4 V 5.5 V |
5.5 V 0.4 V |
" " " |
0.4 V |
5.5 V " " |
SIA SIB CLK |
7/ |
||||||||||||
IIL2 |
" |
24 |
" |
0.4 V |
" |
CLR |
8/ |
||||||||||||||
IIH1 " " |
3010 " " |
25 26 27 |
2.4 V GND |
GND 2.4 V |
" " " |
2.4 V |
" " " |
SIA SIB CLK |
40 " " |
µA " " |
|||||||||||
IIH2 " " |
" " " |
28 29 30 |
5.5 V GND |
GND 5.5 V |
" " " |
5.5 V |
" " " |
SIA SIB CLK |
100 " " |
" " " |
|||||||||||
IIH3 |
" |
31 |
" |
2.4 V |
" |
CLR |
9/ |
" |
|||||||||||||
IIH4 |
" |
32 |
" |
5.5 V |
" |
CLR |
10/ |
" |
See footnotes at end of device type 03.