MIL-M-38510I107D
Parameter |
Test |
IL (mA) |
Switch positions |
Measure |
Measured parameters equation |
Units |
|||
S1 |
S2 |
S3 |
Value |
Units |
|||||
ISCD |
9, 22, 35 |
-5 |
1 |
2 |
2 |
I1 |
mA |
ISCD = I1 |
mA |
-5 |
5 |
2 |
2 |
I2 |
mA |
ISCD = I2 |
|||
ISCD (line) |
10, 23, 36 |
-5 |
1 |
2 |
1 |
V1 |
V |
ISCD = IO(V2 - V1) (line) |
mA |
-5 |
5 |
2 |
1 |
V2 |
V |
||||
ISCD (load) |
11, 24, 37 |
-5 |
3 |
3 |
1 |
V3 |
V |
ISCD = IO (V4 - V3) (load) |
mA |
See notes 3 and 7 |
3 |
3 |
1 |
V4 |
V |
||||
IOS |
12, 25,38 |
See note 6 |
6 |
1 |
2 |
IL |
A |
IOS = IL |
A |
NOTES:
1. R = 2 ν ±1 percent for case X; R = 1 ν ±1 percent for case Y.
2. The pulse generator has the following characteristics:
Variable amplitude, pulse width = 50 μs and PRR = 200 Hz.
Pulse amplitude is adjusted to set the load current by monitoring the voltage drop across R.
3. IL = -0.5 A for case X.
4. +25°C ≤ TA ≤ +125°C; VOUT I T = (VOUT at +25°C) - (VOUT at +125°C) x 10.
5. -55°C ≤ TA ≤ +25°C; VOUT I T = (VOUT at -55°C) - (VOUT at +25°C) x 12.5.
6. One second maximum test duration.
7. IL = 1.5 A for case Y.
8. IL = -100 mA for case X; IL = -1.0 A for case Y.
FIGURE 11. Test circuit for static and dynamic test for device type 01 - Continued.
37
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business