MIL-M-38510/107D
TABLE I. Electrical performance characteristics for device type 07. 4/
Test |
Symbol |
Conditions -55°C TA +125°C see figure 5 and 3.5, unless otherwise specified |
Limits |
Unit |
|||
Input voltage |
Load current |
Other |
Min |
Max |
|||
Output voltage |
VOUT |
VIN = 15 V |
IL = -5 mA, -1.0 A |
11.40 |
12.60 |
V |
|
VIN = 27 V |
IL = -5 mA, -1.0 A |
11.40 |
12.60 |
||||
VIN = 35 V |
IL = -5 mA, -0.1 A |
11.40 |
12.60 |
||||
VIN = 17 V |
IL = -5 mA |
TA = 150°C |
11.28 |
12.72 |
|||
Line regulation |
VRLINE |
15 V VIN 35 V |
IL = -0.1 A |
-360 |
360 |
mV |
|
15 V VIN 32 V |
IL = -0.5 A |
-120 |
120 |
||||
Load regulation |
VRLOAD |
VIN = 17 V |
-1.0 A IL -5 mA |
-240 |
240 |
mV |
|
VIN = 35 V |
-0.1 A IL -5 mA |
-360 |
360 |
||||
Standby current drain |
ISCD |
VIN = 17 V |
IL = -5 mA |
-7.0 |
-0.5 |
mA |
|
VIN = 35 V |
IL = -5 mA |
-8.0 |
-0.5 |
||||
Standby current drain change (versus line voltage) |
ISCD (line) |
15 V VIN 35 V |
IL = -5 mA |
-1.0 |
1.0 |
mA |
|
Standby current drain change (versus load current) |
ISCD (load) |
VIN = 17 V |
-1.0 A IL -5 mA |
-0.5 |
0.5 |
mA |
|
Output short 2/ 5/ circuit current |
IOS |
VIN = 17 V |
-3.50 |
-0.02 |
A |
||
VIN = 32 V |
-2.50 |
-0.02 |
|||||
VIN = 35 V |
-2.00 |
-0.02 |
|||||
Overload current 6/ |
IOL |
VIN = 15 V, forced VOUT = -1.13 V |
See figure 6 |
-4.0 |
-1.0 |
A |
See footnotes at end of table.