MIL-M-385101107D
TABLE I. Electrical performance characteristics for device type 02. 41
Test |
Symbol |
Conditions -55°C = TA = +125°C see figure 5 and 3.5, unless otherwise specified |
Limits |
Unit |
|||
Input voltage |
Load current |
Other |
Min |
Max |
|||
Output voltage |
VOUT |
VIN = 8 V |
IL = -5 mA, -0.5 A |
4.75 |
5.25 |
V |
|
VIN = 20 V |
IL = -5 mA, -0.5 A |
4.75 |
5.25 |
||||
VIN = 35 V |
IL = -5 mA, -50 mA |
4.75 |
5.25 |
||||
VIN = 10 V |
IL = -5 mA |
TA = 150°C |
4.70 |
5.30 |
|||
Line regulation |
VRLINE |
8 V = VIN = 35 V |
IL = -50 mA |
-150 |
150 |
mV |
|
8 V = VIN = 25 V |
IL = -350 mA |
-50 |
50 |
||||
Load regulation |
VRLOAD |
VIN = 10 V |
-500 mA = IL = -5 mA |
-100 |
100 |
mV |
|
VIN = 35 V |
-50 mA = IL = -5 mA |
-150 |
150 |
||||
Standby current drain |
ISCD |
VIN = 10 V |
IL = -5 mA |
-7.0 |
-0.5 |
mA |
|
VIN = 35 V |
IL = -5 mA |
-8.0 |
-0.5 |
||||
Standby current drain change (versus line voltage) |
ISCD (line) |
8 V = VIN = 35 V |
IL = -5 mA |
-1.0 |
1.0 |
mA |
|
Standby current drain change (versus load current) |
ISCD (load) |
VIN = 10 V |
-500 mA = IL = -5 mA |
-0.5 |
0.5 |
mA |
|
Output short 21 51 circuit current |
IOS |
VIN = 10 V |
-2.00 |
-0.01 |
A |
||
VIN = 25 V |
-1.50 |
-0.01 |
|||||
VIN = 35 V |
-1.00 |
-0.01 |
|||||
Overload current 61 |
IOL |
VIN = 8 V, forced VOUT = -0.48 V |
See figure 6 |
-2.0 |
-0.5 |
A |
See footnotes at end of table.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business