MIL-M-38510/1070
0evice types |
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
VIN |
10 V |
10 V |
17 V |
20 V |
30 V |
10 V |
17 V |
20 V |
30 V |
*RL |
100 ν ** |
100 ν |
243 ν |
301 ν |
487 ν |
49.9 ν |
121 ν |
150 ν |
243 ν |
* Load resistor RL shall be type RER 70 or equivalent.
** This value shall be used for case X. For case Y use RL = 49.9 ν.
NOTES:
1. The pulse characteristics shall be established under load while the 0UT is operating. tTHL = tTLH = 1.0 μs.
tp2 = 25 μs at 3% duty cycle.
VPULSE = 0.2 V for device types 01 (case X), 02, 03, 04, and 05. VPULSE = 0.4 V for device types 01 (case Y), 06, 07, 08, and 09.
2. VOUT = 400 mV maximum for device type 01 (case X).
VOUT = 800 mV maximum for device type 01 (case Y).
VOUT = 500 mV maximum for device types 02 - 05.
VOUT = 1000 mV maximum for device types 06 - 09.
(These values guarantee the specified limits for load transient response).
3. Oscilloscope minimum bandwidth shall be 5 MHz.
FIGURE 10. Load transient response test circuit for all devices.
35
For Parts Inquires call Parts Hangar, Inc (727) 493-0744