TABLE III. Group A inspection for device type 06 - Continued.
Terminal conditions (pins not designated may be high > 2.0 V, low < 0.8 V, or open).
Subgroup |
Symbol |
MIL- ST0-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
CLR |
Q1 |
Q1 |
01 |
02 |
Q2 |
Q2 |
GN0 |
CLK |
Q3 |
Q3 |
03 |
04 |
Q4 |
Q4 |
VCC |
Min |
Max |
|||||
10 TC = +125°C |
tPHL1 |
Fig. 15 |
143-150 |
Same tests and terminal conditions as for subgroup 9, except TC = +125°C and limits are as shown. |
2.0 |
23.0 |
ns |
||||||||||||||||
tPHL3 |
Fig. 13 |
151-154 |
" |
23.0 |
" |
||||||||||||||||||
tPHL2 |
Fig. 13 |
155-158 |
" |
29.0 |
" |
||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55°C. |
11 C = Normal clock pulse.
0 = Momentary connection: 5.0 V to momentary GN0 to 5.0 V occurs before measurement is made.
21 For circuit B, IOS(max) is -110 mA.
31 Only a summary of attributes data is required.
41 Inputs: A = 2.4 V minimum, B = 0.4 V.
51 Outputs: H � 1.5 V, L ≤ 1.5 V.
61 fMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business