TABLE III. Group A inspection for device type 06.
Terminal conditions (pins not designated may be high > 2.0 V, low < 0.8 V, or open).
Subgroup |
Symbol |
MIL- ST0-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
CLR |
Q1 |
Q1 |
01 |
02 |
Q2 |
Q2 |
GN0 |
CLK |
Q3 |
Q3 |
03 |
04 |
Q4 |
Q4 |
VCC |
Min |
Max |
|||||
1 TC = +25°C |
VOH |
3006 " " " " " " " " " " " |
1 2 3 4 5 6 7 8 9 10 11 12 |
0 1/ " " " " " " " 0.8 V " " " |
-1 mA |
-1 mA -1 mA |
2.0 V 0.8 V |
2.0 V 0.8 V |
-1 mA -1 mA |
-1 mA |
GN0 " " " " " " " " " " " |
C " " " " " " " |
-1 mA |
-1 mA -1 mA |
2.0 V 0.8 V |
2.0 V 0.8 V |
-1 mA -1 mA |
-1 mA |
4.5 V " " " " " " " " " " " |
Q1 Q1 Q2 Q2 Q3 Q3 Q4 Q4 Q1 Q2 Q3 Q4 |
2.5 " " " " " " " " " " " |
V " " " " " " " " " " " |
|
VOL |
3007 " " " " " " " " " " " |
13 14 15 16 17 18 19 20 21 22 23 24 |
0 " " " " " " " 0.8 V " " " |
20 mA 20 mA |
20 mA |
2.0 V 0.8 V |
2.0 V 0.8 V |
20 mA |
20 mA 20 mA |
" " " " " " " " " " " " |
C " " " " " " " |
20 mA 20 mA |
20 mA |
2.0 V 0.8 V |
2.0 V 0.8 V |
20 mA |
20 mA 20 mA |
" " " " " " " " " " " " |
Q1 Q1 Q2 Q2 Q3 Q3 Q4 Q4 Q1 Q2 Q3 Q4 |
0.5 " " " " " " " " " " " |
" " " " " " " " " " " " |
||
VIC |
25 26 27 28 29 30 |
-18 mA |
-18 mA |
-18 mA |
" " " " " " |
-18 mA |
-18 mA |
-18 mA |
" " " " " " |
CLR 01 02 CLK 03 04 |
-1.2 " " " " " |
" " " " " " |
|||||||||||
IIL1 |
3009 " " " " " |
31 32 33 34 35 36 |
0.5 V |
0.5 V |
0.5 V |
" " " " " " |
0.5 V |
0.5 V |
0.5 V |
5.5 V " " " " " |
CLR 01 02 CLK 03 04 |
-1.0 " " " " " |
-2.0 " " " " " |
mA " " " " " |
See footnotes at end of device type 06.