MIL-M-3851O/71D
Device type O1 Device type O2
Inputs |
Outputs |
||||
Preset |
Clear |
Clock |
D |
Q |
Q |
L |
H |
x |
x |
H |
L |
H |
L |
x |
x |
L |
H |
L |
L |
x |
x |
H* |
H* |
H |
H |
t |
H |
H |
L |
H |
H |
t |
L |
L |
H |
H |
H |
L |
x |
QO |
QO |
Device type O3 Device type O4
Inputs |
Outputs |
||||
Preset |
Clock |
J |
K |
Q |
Q |
L |
x |
x |
x |
H |
L |
H |
↓ |
L |
L |
QO |
QO |
H |
↓ |
H |
L |
H |
L |
H |
↓ |
L |
H |
L |
H |
H |
↓ |
H |
H |
Toggle |
|
H |
H |
x |
x |
QO |
QO |
H = High level (steady state). L = Low level (steady state). x = Irrelevant.
t = Transition from low to high level.
↓ = Transition from high to low level.
QO = The level of Q before the indicated input conditions were established.
Toggle: Each output changes to the complement of its previous level on each active transition (pulse) of the clock.
* This configuration is unstable; that is, it will not persist when preset and clear inputs return to their inactive (high)
level.
Device types O5 and O6 (each flip-flop)
t = device type O6 only.
Figure 3. Truth table.