TABLE III. Group A inspection for device type 06.
Terminal conditions (pins not designated may be high > 2.0 V, low < 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
CLR |
Q1 |
Q1 |
D1 |
D2 |
Q2 |
Q2 |
GND |
CLK |
Q3 |
Q3 |
D3 |
D4 |
Q4 |
Q4 |
VCC |
Min |
Max |
|||||
1 TC = +25°C |
IIH1 |
3010 " " " " " |
37 38 39 40 41 42 |
2.7 V |
2.7 V |
2.7 V |
GND " " " " " |
2.7 V |
2.7 V |
2.7 V |
5.5 V " " " " " |
CLR D1 D2 CLK D3 D4 |
50 " " " " " |
µA " " " " " |
|||||||||
IIH5 |
" " " " " " |
43 44 45 46 47 48 |
5.5 V |
5.5 V |
5.5 V |
" " " " " " |
5.5 V |
5.5 V |
5.5 V |
" " " " " " |
CLR D1 D2 CLK D3 D4 |
1.0 " " " " " |
mA " " " " " |
||||||||||
IOS |
3011 " " " " " " " |
49 50 51 52 53 54 55 56 |
5.5 V " " " " " " " |
GND |
GND |
5.5 V GND |
5.5 V GND |
GND |
GND |
" " " " " " " " |
C " " " " " " " |
GND |
GND |
5.5 V GND |
5.5 V GND |
GND |
GND |
" " " " " " " " |
Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4 |
-40 " " " " " " " |
-100 21 " " " " " " |
" " " " " " " " |
|
ICC |
3005 |
57 |
" |
5.5 V |
5.5 V |
" |
D |
5.5 V |
5.5 V |
" |
VCC |
96 |
" |
||||||||||
ICEX |
58 59 60 61 62 63 64 65 |
D " " " " " " " |
5.5 V |
5.5 V |
5.5 V GND |
5.5 V GND |
5.5 V |
5.5 V |
" " " " " " " " |
D " " " " " " " |
5.5 V |
5.5 V |
5.5 V GND |
5.5 V GND |
5.5 V |
5.5 V |
" " " " " " " " |
Q1 Q1 Q2 Q2 Q3 Q3 Q4 Q4 |
250 " " " " " " " |
µA " " " " " " " |
|||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. VOL (max) = 0.45 V, VIL = 0.7 V. |
||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
See footnotes at end of device type 06.