M1L-M-38510/502A
TABLE 11. Electrical test requirements.
M1L-PRF-38535 test requirements |
Subgroups (per table 111) 2/, 3/ |
|
Class S devices |
Class B devices |
|
1nterim electrical parameters (pre burn-in) |
1 |
1 |
Final electrical test parameters for unprogrammed devices |
1*, 2, 3, 7*, 8 |
1*, 2, 3, 7*, 8 |
Final electrical test parameters for programmed devices |
1*, 2, 3, 7*, 8, 9, 10, 11 |
1*, 2, 3, 7*, 8, 9 |
Group A test requirements |
1, 2, 3, 7, 8, 9, 10, 11 |
1, 2, 3, 7, 8, 9, 10, 11 |
Group B electrical test parameters When using the method 5005 QC1 option |
1, 2, 3, 7, 8, 9, 10, 11 |
N/A |
Group C end-point electrical parameters |
1, 2, 3, 7, 8, 9, 10, 11 |
1, 2, 3, 7, 8 |
Group D end-point electrical parameters |
1, 2, 3, 7, 8 |
1, 2, 3, 7, 8 |
1/ (*) indicates PDA applies to subgroups 1 and 7.
2/ Any or all subgroups may be combined when using high-speed testers.
3/ Subgroup 7 and 8 shall consist of verifying the pattern specified.
Pin Number Case X |
Device Type 01 and 02 |
1 |
FE |
2 |
17 |
3 |
16 |
4 |
15 |
5 |
14 |
6 |
13 |
7 |
12 |
8 |
11 |
9 |
10 |
10 |
F7 |
11 |
F6 |
12 |
F5 |
13 |
F4 |
14 |
GND |
15 |
F3 |
16 |
F2 |
17 |
F1 |
18 |
F0 |
19 |
CE |
20 |
115 |
21 |
114 |
22 |
113 |
23 |
112 |
24 |
111 |
25 |
110 |
26 |
19 |
27 |
18 |
28 |
vCC |
F1GURE 1. Terminal connections.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business