TABLE III. Group A inspection for device type 05 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F,Z |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Units |
||||||||||||||||||||||
Subgroup 7 TA = 25°C |
Subgroup 8 |
|||||||||||||||||||||||||||
Symbol |
C |
Q1 |
D1 |
D2 |
Q2 |
D3 |
Q3 |
VSS |
CLK |
Q4 |
D4 |
Q5 |
D5 |
D6 |
Q6 |
VDD |
TA = 125°C |
TA = -55°C |
||||||||||
Test No. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||||
Truth table test " " " " " " |
3014 " " " " " " " " |
100 101 102 103 104 105 106 107 108 |
GND 5.0V " " " " " GND GND |
L L H H L L H L L |
5.0V 5.0V 5.0V GND GND 5.0V 5.0V 5.0V GND |
5.0V 5.0V 5.0V GND GND 5.0V 5.0V 5.0V GND |
L L H H L L H L L |
5.0V 5.0V 5.0V GND GND 5.0V 5.0V 5.0V GND |
L L H H L L H L L |
GND " " " " " " " " |
5.0V GND 5.0V GND 5.0V GND 5.0V 5.0V GND |
L L H H L L H L L |
5.0V 5.0V 5.0V GND GND 5.0V 5.0V 5.0V GND |
L L H H L L H L L |
5.0V 5.0V 5.0V GND GND 5.0V 5.0V 5.0V GND |
5.0V 5.0V 5.0V GND GND 5.0V 5.0V 5.0V GND |
L L H H L L H L L |
5.0V " " " " " " " " |
All outputs " " " " " " " |
See notes 4/, 5/ |
||||||||
Subgroup 9 TA = 25°C |
Subgroup 10 TA = 125°C |
Subgroup 11 TA = -55°C |
||||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||||||
tPHL1 " " " " " |
3003 Fig. 4 " " " " |
109 110 111 112 113 114 |
5.0V " " " " " |
OUT |
IN2 GND " " " " |
GND IN2 GND " " " |
OUT |
GND GND IN2 GND " " |
OUT |
GND " " " " " |
IN1 " " " " " |
OUT |
GND GND GND IN2 GND " |
OUT |
GND " " " IN2 GND |
GND " " " " IN2 |
OUT |
5.0V " " " " " |
CLK to Q1 CLK to Q2 CLK to Q3 CLK to Q4 CLK to Q5 CLK to Q6 |
15 " " " " " |
300 " " " " " |
21 " " " " " |
420 " " " " " |
15 " " " " " |
300 " " " " " |
ns " " " " " |
||
tPHL2 " " " " " |
" " " " " " |
115 116 117 118 119 120 |
IN2 " " " " " |
OUT |
5.0V GND " " " " |
" 5.0V GND " " " |
OUT |
" " 5.0V GND " " |
OUT |
" " " " " " |
" " " " " " |
OUT |
" " " 5.0V GND " |
OUT |
" " " " 5.0V GND |
GND " " " " 5.0V |
OUT |
" " " " " " |
C to Q1 C to Q2 C to Q3 C to Q4 C to Q5 C to Q6 |
15 " " " " " |
300 " " " " " |
21 " " " " " |
420 " " " " " |
15 " " " " " |
300 " " " " " |
" " " " " " |
||
tPLH1 " " |
" " " |
121 122 123 |
5.0V 5.0V 5.0V |
OUT |
IN2 GND GND |
" IN2 GND |
OUT |
" " IN2 |
OUT |
" " " |
IN1 IN1 IN1 |
" " " |
" " " |
GND GND GND |
" " " |
CLK to Q1 CLK to Q2 CLK to Q3 |
15 15 15 |
300 300 300 |
21 21 21 |
420 420 420 |
15 15 15 |
300 300 300 |
" " " |
See footnotes at end of device type 05.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business