MIL-M-38510/175C
NOTES:
1. Pulse generator number 1 has the following characteristics:
VGEN = VDD ±1%, tPH = 1.0 ±0.1 μs, tr and tf = 20 ±2 ns and PRR = 200 kHz.
2. Pulse generators number 2 have the following characteristics:
VGEN = VDD ±1%, tPH = 1.0 ±0.1 μs, tr and tf = 20 ±2 ns and PRR = 100 kHz.
3. Requirements for minimum clock frequency (fCL), tr, tf, tSHL, tSLH, tp(CL), and tp(R) are
established by setting the parameter to the limits given in table III and observing proper output state change.
4. Complete terminal conditions are as specified in table III.
5. For the tPLZ and tPZL measurements, the output is tied to VDD through a 1 kν resistor.
6. For the tPHZ and tPZH measurements, the output is tied to VSS through a 1 kν resistor.
FIGURE 4. Switching waveforms and test circuit.
16
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business