MIL-M-38510/175C
9/ Connect RX1, CX1, RX2, and CX2 using the values in the table below:
Test |
RX1, 2 |
CX1, 2 |
Kν ± 10% |
pF ± 10% |
|
tPLH1 |
10 |
100 |
tPHL1 |
10 |
100 |
tPLH2 * |
10 |
100 |
tPHL2 * |
10 |
100 |
tTLH1 |
10 |
100 |
tTHL1 |
10 |
100 |
tTHL2 |
10 |
0.01 ∝F |
tTHL2 |
10 |
0.1 ∝F |
tTHL2 |
10 |
1.0 ∝F |
tTLH2 |
10 |
0.01 ∝F |
tTLH2 |
10 |
0.1 ∝F |
tTLH2 |
10 |
1.0 ∝F |
* Reset pulse shall be applied before the RXCX times out.
10/ The following terminal conditions shall apply. The tests shall be performed using the logical timing sequence of test numbers 86 through 109. The parenthetical terminal conditions are used for the "truth table test". The nonparenthetical terminal conditions are used for the "VIH1, 2, 3/VIL1, 2, 3" tests. The RX1, RX2 terminal conditions are for both of these tests.
Input/output conditions
VDD |
Input levels |
Output levels |
RX1, RX2 Input levels |
|||
H |
L |
H |
L |
H |
L |
|
(= 5.0 V) 5.0 V |
Max |
Min 1.5V (VSS) |
Min (VDD - 0.5 V) 4.5V |
Max (VSS = 0.8 V) 0.5V |
VDD Through 22 kν ±10% |
VSS Through 22 kν ±10% |
(VDD) 3.5 V |
||||||
10.0V |
3.0V |
9.0V |
1.0V |
|||
7.0V |
||||||
15.0V ( 18.0 V) |
4.0V (VSS) |
13.5V (VDD - 0.5 V) |
1.5V (VSS + 0.5 V) |
|||
(VDD) 11.0V |