TABLE III. Group A inspection for device type 05.
Symbol |
MIL- STD- 883 method |
Cases E,F,Z |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Units |
||||||||||||||||||||
Subgroup 1 TA = 25°C |
Subgroup 2 TA = 125°C |
Subgroup 3 TA = -55°C |
||||||||||||||||||||||||
Symbol |
C |
Q1 |
D1 |
D2 |
Q2 |
D3 |
Q3 |
VSS |
CLK |
Q4 |
D4 |
Q5 |
D5 |
D6 |
Q6 |
VDD |
||||||||||
Test No. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
VIC (pos) " " " " " " |
1 2 3 4 5 6 7 8 |
1mA |
1mA |
1mA |
1mA |
1mA |
1mA |
1mA |
1mA |
GND " " " " " " " |
C D1 D2 D3 CLK D4 D5 D6 |
1.5 " " " " " " " |
Vdc " " " " " " " |
|||||||||||||
VIC (neg) " " " " " " |
9 10 11 12 13 14 15 16 |
-1mA |
-1mA |
-1mA |
-1mA |
GND " " " " " " " |
-1mA |
-1mA |
-1mA |
-1mA |
C D1 D2 D3 CLK D4 D5 D6 |
-6.0 " " " " " " " |
" " " " " " " " |
|||||||||||||
ISS " " " |
3005 " " " |
17 18 19 20 |
GND 18.0V 18.0V 18.0V |
18.0V 18.0V GND GND |
18.0V 18.0V GND GND |
18.0V 18.0V GND GND |
" " " " |
GND 7/ 7/ GND |
18.0V 18.0V GND GND |
18.0V 18.0V GND GND |
18.0V 18.0V GND GND |
18.0V " " " |
VSS " " " |
-.075 " " " |
-2.5 " " " |
∝A " " " |
||||||||||
VOH1 " " " " " |
3006 " " " " " |
21 22 23 24 25 26 |
15.0V " " " " " |
15.0V " " " " " |
15.0V " " " " " |
15.0V " " " " " |
" " " " " " |
8/ 15.0V " " " " |
15.0V " " " " " |
15.0V " " " " " |
15.0V " " " " " |
15.0V " " " " " |
Q1 Q2 Q3 Q4 Q5 Q6 |
14.95 " " " " " |
14.95 " " " " " |
14.95 " " " " " |
Vdc " " " " " |