MIL-M-38510/175C
Device type 01
Truth table |
||||||
RESE T |
CLOC K |
Data input disable |
Data |
Output next state |
||
G1 |
G2 |
D |
Q |
|||
H |
x |
x |
x |
x |
L |
|
L |
L |
x |
x |
x |
Q |
NC |
L |
τ |
H |
x |
x |
Q |
NC |
L |
τ |
x |
H |
x |
Q |
NC |
L |
τ |
L |
L |
H |
H |
|
L |
τ |
L |
L |
L |
L |
|
L |
H |
x |
x |
x |
Q |
NC |
L |
? |
x |
x |
x |
Q |
NC |
When either output disable M or N is high, the outputs are disabled (high impedance state);
however sequential operation of the flip-flops is not affected. H = High level voltage
L = Low level voltage
τ = Low-to-high transition of the clock
↓ = High-to-low transiton of the clock x = Don't care
Device type 02 and 03
Synchronous operation Asynchronous operation
(S = 0, R = 0) (J and K don't care)
Truth table |
|||
Inputs before positive clock transition |
Outputs after positive clock transition |
||
Inputs |
Outputs |
||
J * |
K * |
Q |
Q |
L |
L |
NC |
NC |
L |
H |
L |
H |
H |
L |
H |
L |
H |
H |
Toggles |
* Device type 02
For device type 02
J = J1.J2.J3
K = K1.K2.K3
For device type 03
J = J1.J2.J3
K = K1.K2.K3
H = high level voltage L = Low level voltage NC = No change
FIGURE 3. Truth tables.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business