TABLE III. Group A inspection for device type 06 - Continued.
Symbol |
MIL- ST0- 883 method |
Cases R, S, and 2 |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
Subgroup 9 TC = +25°C |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C |
||||||||
Test no. |
OE |
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
GN0 |
ENC |
8Q |
7Q |
6Q |
5Q |
4Q |
3Q |
2Q |
1Q |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tTHL |
3004 (Fig. 3) |
192 193 194 195 196 197 198 199 |
GN0 " " " " " " " |
IN |
IN |
IN |
IN |
IN |
IN |
IN |
IN |
GN0 " " " " " " " |
4.5V " " " " " " " |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
4.5V " " " " " " " |
1Q 2Q 3Q 4Q 5Q 6Q 7Q 8Q |
2 " " " " " " " |
12 " " " " " " " |
2 " " " " " " " |
16 " " " " " " " |
2 " " " " " " " |
12 " " " " " " " |
ns " " " " " " " |
tTLH |
3004 (Fig. 3) |
200- 207 |
Same tests, terminal conditions and limits as specified above for tTHL. |