TABLE III. Group A inspection for device type 02 - Continued.
Symbol |
MIL- STD- 883 method |
Case 2 |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
Subgroup 7 TC = +25°C |
Subgroup 8 TC = +125°C |
Subgroup 8 TC = -55°C |
||||||||
Cases E and F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
||||||||||
Test no. |
A0 |
A1 |
A2 |
Q0 |
Q1 |
Q2 |
Q3 |
GND |
Q4 |
Q5 |
Q6 |
Q7 |
Data IN |
EN |
CLR |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
Truth table 3/ |
3014 |
101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 |
A B B B A A A B B B A A A B B B A A |
B A " " " " " B " " " " " A " " " " |
B " " " " " " A " " " " " " " " " " |
H " " " " " " " " " " " " " " " " " |
H " " " " " " " " " " " " " " " " " |
L " H " " " " " " " " " " " " " " " |
L " " " " H " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " " " " |
L " " " " " " " H " " " " " " " " " |
L " " " " " " " " " " H " " " " " " |
L " " " " " " " " " " " " " H " " " |
H " " " " " " " " " " " " " " " " " |
A " " " " " " " " " " " " " " " " " |
A A B A A B A A B A A B A A B A A B |
A " " " " " " " " " " " " " " " " " |
4.5V " " " " " " " " " " " " " " " " " |
All Outputs 4/ " " " " " " " " " " " " " " " |
|||||||
Subgroup 9 TC = +25°C |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C |
||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||||
tPHL1 |
3003 (Fig. 3) |
119 120 121 122 123 124 125 126 |
GND 4.5V GND 4.5V GND 4.5V GND 4.5V |
GND GND 4.5V 4.5V GND GND 4.5V 4.5V |
GND GND GND GND 4.5V 4.5V 4.5V 4.5V |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " |
OUT |
OUT |
OUT |
OUT |
IN " " " " " " " |
GND 5/ " " " " " " |
4.5V " " " " " " " |
4.5V " " " " " " " |
Data to Q0 Data to Q1 Data to Q2 Data to Q3 Data to Q4 Data to Q5 Data to Q6 Data to Q7 |
5 " " " " " " " |
37 " " " " " " " |
5 " " " " " " " |
43 " " " " " " " |
5 " " " " " " " |
37 " " " " " " " |
ns " " " " " " " |
tPLH1 |
3003 (Fig. 3) |
127- 134 |
Same tests and terminal conditions and limits as specified above for tPHL1. |
|||||||||||||||||||||||
tPHL2 |
3003 (Fig. 3) |
135 136 137 138 139 140 141 142 |
GND 4.5V GND 4.5V GND 4.5V GND 4.5V |
GND GND 4.5V 4.5V GND GND 4.5V 4.5V |
GND GND GND GND 4.5V 4.5V 4.5V 4.5V |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " |
OUT |
OUT |
OUT |
OUT |
4.5V " " " " " " " |
IN " " " " " " " |
4.5V " " " " " " " |
4.5V " " " " " " " |
EN to Q0 EN to Q1 EN to Q2 EN to Q3 EN to Q4 EN to Q5 EN to Q6 EN to Q7 |
7 " " " " " " " |
35 " " " " " " " |
7 " " " " " " " |
47 " " " " " " " |
7 " " " " " " " |
35 " " " " " " " |
ns " " " " " " " |
tPLH2 |
3003 (Fig. 3) |
143- 150 |
Same tests and terminal conditions and limits as specified above for tPHL2, with the exception that Data IN is at GND. |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business