MIL-M-38510/654A
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ TC = +125°C unless otherwise specified |
Device type |
VCC |
Limits |
Unit |
|
Min |
Max |
||||||
Propagation delay time, clear to outputs |
tPHL4 6/, 7/ |
CL = 50 pF ± 10% |
02 |
4.5 V |
5 |
36 |
ns |
Output enable time |
tPZH, tPZL 6/, 7/ |
CL = 50 pF ± 10% RL = 1k0 ± 10% |
03 |
5 |
35 |
||
04 |
5 |
35 |
|||||
05,06 |
4 |
35 |
|||||
53 |
5 |
41 |
|||||
Output disable time |
tPHZ, tPLZ 6/, 7/ |
03 |
5 |
35 |
|||
04 |
5 |
35 |
|||||
05,06 |
3 |
35 |
|||||
53 |
5 |
41 |
|||||
Transition delay time |
tTHL, tTLH 6/, 7/ |
CL = 50 pF ± 10% |
01 |
3 |
20 |
||
02 |
3 |
20 |
|||||
03,04, 53 |
2 |
16 |
|||||
05 |
2 |
16 |
|||||
06 |
2 |
16 |
1/ Complete terminal conditions shall be as specified in table III.
2/ Guaranteed but not tested.
3/ ICC + ICC� = Total supply current.
4/ Power dissipation capacitance (CPD) per latch.
5/ IOZL: Set output to high state.
IOZH: Set output to low state.
6/ Tested at VCC = 4.5 V at 125°C for sample testing and at VCC = 4.5 V at 25°C for screening. Guaranteed at other VCC voltages and temperatures. See table IA and the exception in 4.4.1d.
7/ For propagation and transition delay times at VCC = 2.0 V, increase limit by a factor of 5. For propagation and transition delay times at VCC = 6.0 V, decrease limit by a factor of .85.
TABLE IA. Calculated dynamic values at -55°C /+25°C case temperature.
VCC |
TC = °C |
|
+125 |
-55/+25 |
|
2.0 V 4.5 V 6.0 V |
5 t 1→ ↓ 0.85 |
5 x 0.75 t →0.75 ↓ 0.85 x 0.75 |
NOTE: Normalized numbers (+125°C = 1).
The 2.0 V and 6.0 V numbers are derived
from their 4.5 V integer value (rounding off according 5/4).
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business