TABLE III. Group A inspection for device type O5 - Continued.
Symbol |
MIL- ST0- 883 method |
Cases R, S, and 2 |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
1O |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
2O |
Subgroup 9 TC = +25°C |
Subgroup 1O TC = +125°C |
Subgroup 11 TC = -55°C |
||||||||
Test no. |
OE |
0O |
01 |
02 |
03 |
04 |
05 |
06 |
07 |
GN0 |
LE |
Q7 |
Q6 |
Q5 |
Q4 |
Q3 |
Q2 |
Q1 |
QO |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tPLZ |
3OO3 (Fig. 3) |
167 168 169 17O 171 172 173 174 |
IN " " " " " " " |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
GN0 " " " " " " " |
4.5 V " " " " " " " |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
4.5 V " " " " " " " |
OE to QO OE to Q1 OE to Q2 OE to Q3 OE to Q4 OE to Q5 OE to Q6 OE to Q7 |
3 " " " " " " " |
26 " " " " " " " |
3 " " " " " " " |
35 " " " " " " " |
3 " " " " " " " |
26 " " " " " " " |
ns " " " " " " " |
tPZH |
3OO3 (Fig. 3) |
175 176 177 178 179 18O 181 182 |
" " " " " " " " |
O.OV |
O.OV |
O.OV |
O.OV |
O.OV |
O.OV |
O.OV |
O.OV |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
OE to QO OE to Q1 OE to Q2 OE to Q3 OE to Q4 OE to Q5 OE to Q6 OE to Q7 |
4 " " " " " " " |
26 " " " " " " " |
4 " " " " " " " |
35 " " " " " " " |
4 " " " " " " " |
26 " " " " " " " |
" " " " " " " " |
tPZL |
3OO3 (Fig. 3) |
183 184 185 186 187 188 189 19O |
" " " " " " " " |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
4.5V |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
OE to QO OE to Q1 OE to Q2 OE to Q3 OE to Q4 OE to Q5 OE to Q6 OE to Q7 |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
tTHL |
3OO4 (Fig. 3) |
191 192 193 194 195 196 197 198 |
O.OV " " " " " " " |
IN |
IN |
IN |
IN |
IN |
IN |
IN |
IN |
" " " " " " " " |
" " " " " " " " |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " |
QO Q1 Q2 Q3 Q4 Q5 Q6 Q7 |
2 " " " " " " " |
12 " " " " " " " |
2 " " " " " " " |
16 " " " " " " " |
2 " " " " " " " |
12 " " " " " " " |
ns " " " " " " " |
tTLH |
3OO4 (Fig. 3) |
199- 2O6 |
Same tests, terminal conditions and limits as specified above for tTHL. |