TA8LE III. Group A inspection for device type 02 - Continued.
Symbol |
MIL- STD- 883 method |
Case 2 |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
Subgroup 7 TC = +25°C |
Subgroup 8 TC = +125°C |
Subgroup 8 TC = -55°C |
||||||||
Cases C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
||||||||||
Test no. |
1CLR |
1D |
1CLK |
1PRE |
1Q |
1Q |
GND |
2Q |
2Q |
2CLK |
2D |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||||
2PRE |
2CLR |
|||||||||||||||||||||||
Truth table tests 6/ 7/ |
3014 |
89 90 91 |
A A A |
8 A A |
8 8 A |
A A A |
L L H |
H H L |
GND " " |
H H L |
L L H |
A A A |
8 8 A |
8 A A |
A A A |
4.5V " " |
All outputs " |
5/ " " |
5/ " " |
5/ " " |
5/ " " |
5/ " " |
5/ " " |
|
Test limits 8/ |
||||||||||||||||||||||||
Subgroup 9 TC = +25°C |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C |
||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||
fMAX 7/ 9/ |
(Fig. 3) |
92 93 94 95 |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
OUT |
OUT |
GND " " " |
OUT |
OUT |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
4.5V " " " |
1Q 1Q 2Q 2Q |
28 " " " |
21 " " " |
28 " " " |
MHz " " " |
|||
tPHL1 7/ |
3003 (Fig. 3) |
96 97 98 99 |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
OUT |
OUT |
" " " " |
OUT |
OUT |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
" " " " |
1CLK to 1Q 2CLK to 2Q 1CLK to 1Q 2CLK to 2Q |
5 " " " |
31 " " " |
5 " " " |
41 " " " |
5 " " " |
31 " " " |
ns " " " |
tPLH1 7/ |
3003 (Fig. 3) |
100 101 102 103 |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
OUT |
OUT |
" " " " |
OUT |
OUT |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
" " " " |
1CLK to 1Q 2CLK to 2Q 1CLK to 1Q 2CLK to 2Q |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
tPHL2 7/ |
3003 (Fig. 3) |
104 105 106 107 |
IN 4.5V |
GND GND |
GND GND |
4.5V IN |
OUT |
OUT |
" " " " |
OUT |
OUT |
4.5V IN |
GND GND |
GND GND |
IN 4.5V |
" " " " |
1CLR to 1Q 1PRE to 1Q 2CLR to 2Q 2PRE to 2Q |
" " " " |
41 " " " |
" " " " |
54 " " " |
" " " " |
41 " " " |
" " " " |
tPLH2 7/ |
3003 (Fig. 3) |
108 109 110 111 |
IN 4.5V |
GND GND |
GND GND |
4.5V IN |
OUT |
OUT |
" " " " |
OUT |
OUT |
4.5V IN |
GND GND |
GND GND |
IN 4.5V |
" " " " |
1CLR to 1Q 1PRE to 1Q 2CLR to 2Q 2PRE to 2Q |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
tTHL 7/ |
3004 (Fig. 3) |
112 113 114 115 |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
OUT |
OUT |
" " " " |
OUT |
OUT |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
" " " " |
1Q 2Q 1Q 2Q |
3 " " " |
15 " " " |
3 " " " |
20 " " " |
3 " " " |
15 " " " |
" " " " |
tTLH 7/ |
3004 (Fig. 3) |
116 117 118 119 |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
OUT |
OUT |
" " " " |
OUT |
OUT |
4.5V 4.5V |
IN IN |
IN IN |
4.5V 4.5V |
" " " " |
1Q 2Q 1Q 2Q |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business