MIL-M-38510/6538
NOTES:
1. Clock input pulse characteristics: tr = tf ; 6 ns; tp (clock) ; 27 ns.
2. J or K input pulse characteristics: tr = tf ; 6 ns; tp (J or K) ; 38 ns; thold ; 8 ns; tsetup ; 30 ns.
3. The clock input characteristics for fMAX are as follows: tr = tf ; 6 ns; tp (clock) ; 22 ns; PRR � 23 MHz.
4. CL = 50 pF ±10% (including jig and probe capacitance).
5. Voltage measurements are to be made with respect to network ground terminal.
6. tTLH = tTLH2 - tTLH1 ; tTHL = tTHL2 - tTHL1.
FIGURE 3. Synchronous switching test circuit and waveforms (device type 04) - Continued.
23
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business