MIL-M-38510/6538
NOTES:
1. Clock input pulse characteristics: tr = tf ; 6 ns; tp (clock) ; 24 ns.
2. Data input pulse characteristics: tr = tf ; 6 ns; tp (data) ; 38 ns; tsetup ; 30 ns; thold ; 8 ns.
3. The clock input characteristics for fMAX are as follows: tr = tf ; 6 ns; tp (clock) ; 19 ns; PRR � 26 MHz.
4. CL = 50 pF ±10 % (including test jig and probe capacitance).
5. Voltage measurements are to be made with respect to network ground terminal.
6. tTLH = tTLH1 - tTLH2 ; tTHL = tTHL2 - tTHL1.
FIGURE 3. Synchronous switching test circuit and waveforms (device type 08) - Continued.