MIL-M-3851O/6538
Device type O5
Inputs |
Ouputs |
|||||
PRE |
CLR |
CLK |
J |
K |
Q |
Q |
L |
H |
x |
x |
x |
H |
L |
H |
L |
x |
x |
x |
L |
H |
L |
L |
x |
x |
x |
H * |
H * |
H |
H |
↓ |
L |
L |
QO |
QO |
H |
H |
↓ |
H |
L |
H |
L |
H |
H |
↓ |
L |
H |
L |
H |
H |
H |
↓ |
H |
H |
Toggle |
|
H |
H |
H |
x |
x |
QO |
QO |
Device type O6
Inputs |
Data enable |
Data |
Output |
||
CLR |
CLK |
E1 |
E2 |
D |
Q |
H |
x |
x |
x |
x |
L |
L |
L |
x |
x |
x |
QO |
L |
t |
H |
x |
x |
QO |
L |
t |
x |
H |
x |
QO |
L |
t |
L |
L |
L |
L |
L |
t |
L |
L |
H |
H |
For device type O6: When either OE1 or OE2
(or both) is (are) high, the output is disabled to the high-Z state; however, sequential operation of the flip-flops is not affected.
Device type O7
Inputs |
Output |
||
CLR |
CLK |
D |
Q |
L |
x |
x |
L |
H |
t |
H |
H |
H |
t |
L |
L |
H |
L |
x |
QO |
Device type O8
Inputs |
Outputs |
|||
CLR |
CLK |
D |
Q |
Q |
L |
x |
x |
L |
H |
H |
t |
H |
H |
L |
H |
t |
L |
L |
H |
H |
L |
x |
QO |
QO |
* = This configuration is nonstable x = Pins have no effect on output H = High level voltage
L = Low level voltage
t = Low-to-high transition of the clock
↓ = High-to-low transition of the clock
QO (QO) = The level of Q (Q) before the indicated steady-state input conditions were established
FIGURE 2. Truth tables - Continued.
16
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business