MIL-M-38510/206D
TABLE IVA. Programming characteristics for circuit A.
Parameter |
Symbol |
Limits 1/ |
Unit |
||
Min |
Rec |
Max |
|||
Address input voltage 2/ |
VIH VIL |
2.4 0.0 |
5.0 0.4 |
5.0 0.5 |
V V |
Programing Voltage to VCC low Program verify Verify voltage |
VPH 3/ VPL VPHV VR 4/ |
10.75 0.0 --- 4.5 |
11.0 0.0 5.5 --- |
11.25 1.5 --- 5.5 |
" " " " |
Programming input low current at VPH |
IILP |
--- |
-300 |
-600 |
µA |
Programmed voltage (VCC) transition time |
tTLH tTHL |
1 1 |
5 5 |
10 10 |
µs " |
Programming delay |
tD1 tD2 |
10 1 |
10 5 |
20 5 |
" |
Programming pulse width |
tP 5/ |
90 |
100 |
110 |
" |
Programming duty cycle |
PDC |
--- |
30 |
60 |
% |
Output voltage Enable Disable |
VOPE 6/ VOPD |
10.5 0.0 |
10.5 5.0 |
11.0 5.5 |
V V |
During the programming the chip must be disabled for proper operation.
1/ TC = +25°C.
2/ No inputs should be left open for VIH.
3/ VPH source must be capable of supplying one ampere.
4/ It is recommended that post programming dual verification be made at VR minimum and VR maximum.
5/ Note setup j in programming procedure.
6/ VOPE source must be capable of supplying 10 mA minimum.
33
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business