TABLE III. Group A inspection for device type 06. 1/ - Continued.
Subgroup |
Symbol |
MIL-STD- 883 method |
Case A, B D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Case C |
10 |
12 |
13 |
14 |
2 |
1 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
11 |
|||||||
Test No. |
K1 |
Clock |
Preset |
VCC |
Clear |
NC |
J1 |
J2 |
J* |
Q |
GND |
Q |
K* |
K2 |
Min |
Max |
Unit |
||||
9 TC = 25°C |
FMAX 5/ |
(Fig. 14) |
93 |
2.4 V |
IN |
5.0 V |
5.0 V |
5.0 V |
2.4 V |
2.4 V |
GND |
GND |
OUT |
GND |
2.4 V |
Q |
20 |
MHz |
|||
FMAX 5/ |
(Fig. 14) |
94 |
2.4 V |
IN |
5.0 V |
" |
5.0 V |
2.4 V |
2.4 V |
GND |
OUT |
" |
GND |
2.4 V |
Q |
20 |
MHz |
||||
" |
tPLH |
3003 (Fig. 13) |
95 |
5.0 V |
0.8 V |
IN |
" |
IN |
5.0 V |
5.0 V |
GND |
OUT |
" |
GND |
5.0 V |
Clear to Q |
5 |
50 |
ns |
||
" |
tPLH |
" |
96 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Preset to Q |
" |
" |
" |
||
" |
tPHL |
" |
97 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clear to Q |
" |
" |
" |
||
" |
tPHL |
" |
98 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Preset to Q |
" |
" |
" |
||
" |
(Fig. 15) |
3003 (Fig. 14) |
99 |
2.4 V |
IN |
5.0 V |
" |
5.0 V |
2.4 V |
2.4 V |
GND |
" |
OUT |
GND |
2.4 V |
Clock to Q |
5 |
50 |
ns |
||
" |
tPLH |
100 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
" |
" |
|||
" |
tPHL |
" |
101 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clock to Q |
" |
" |
" |
||
" |
tPHL |
" |
102 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
" |
" |
||
10 TC = 125°C |
FMAX 5/ |
(Fig. 14) |
103 |
2.4 V |
IN |
5.0 V |
" |
5.0 V |
2.4 V |
2.4 V |
GND |
" |
OUT |
GND |
2.4 V |
Q |
15 |
MHz |
|||
FMAX 5/ |
(Fig. 14) |
104 |
2.4 V |
IN |
5.0 V |
" |
5.0 V |
2.4 V |
2.4 V |
GND |
OUT |
" |
GND |
2.4 V |
Q |
15 |
MHz |
||||
" |
tPLH |
3003 (Fig. 13) |
105 |
5.0 V |
0.8 V |
IN |
" |
IN |
5.0 V |
5.0 V |
GND |
OUT |
" |
GND |
5.0 V |
Clear to Q |
5 |
62 |
ns |
||
" |
tPLH |
" |
106 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Preset to Q |
" |
" |
" |
||
" |
tPHL |
" |
107 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clear to Q |
" |
" |
" |
||
" |
tPHL |
" |
108 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Preset to Q |
" |
" |
" |
||
" |
tPLH |
3003 (Fig. 14) |
109 |
2.4 V |
IN |
5.0 V |
" |
5.0 V |
5.0 V |
5.0 V |
GND |
" |
OUT |
GND |
2.4 V |
Clock to Q |
5 |
62 |
ns |
||
" |
tPLH |
110 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
" |
" |
|||
" |
tPHL |
" |
111 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clock to Q |
" |
" |
" |
||
" |
tPHL |
" |
112 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
" |
" |
||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
NOTES:
A = Normal clock pulse.
B = Momentary GND, then 4.5 V.
1/ Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
2/ Input voltages shown are: A = 2.0 V minimum and B = 0.8 V maximum.
3/ Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double comparator; or (b) H � 1.5 V and L < 1.5 V when using a high speed checker single comparator.
4/ Tests shall be performed in sequence.
5 FMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business