TABLE III. Group A inspection for device type 03. 1/ - Continued.
Subgroup |
Symbol |
MIL- STD-883 method |
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Test No. |
J1 |
Q 1 |
Q1 |
K1 |
Q2 |
Q 2 |
GND |
J2 |
Clock 2 |
Clear 2 |
K2 |
Clock 1 |
Clear 1 |
vCC |
Min |
Max |
Unit |
||||
9 TC = 25°C |
FMAX |
(Fig. 7) 6/ |
89 |
2.4 v |
OUT |
2.4 v |
GND |
IN |
5.0 v |
5.0 v |
Q1 |
10 |
MHz |
||||||||
" |
" |
90 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Q 1 |
" |
" |
|||||||||
" |
" |
" |
91 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Q2 |
" |
" |
||||||||
" |
" |
" |
92 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Q 2 |
" |
" |
||||||||
" |
tPLH |
3003 (Fig. 6) |
93 |
2.4 v |
OUT |
GND |
" |
A |
IN |
" |
Clr 1 to Q 1 |
5 |
25 |
ns |
|||||||
" |
tPLH |
" |
94 |
OUT |
" |
2.4 v |
A |
IN |
GND |
" |
Clr 2 to Q 2 |
" |
25 |
" |
|||||||
" |
tPHL |
" |
95 |
2.4 v |
OUT |
GND |
" |
A |
IN |
" |
Clr 1 to Q1 |
" |
40 |
" |
|||||||
" |
tPHL |
" |
96 |
OUT |
" |
2.4 v |
A |
IN |
GND |
" |
Clr 2 to Q2 |
" |
40 |
" |
|||||||
" |
tPLH |
3003 (Fig. 7) |
97 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q1 |
5 |
30 |
ns |
|||||||
" |
" |
98 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q 1 |
" |
" |
" |
||||||||
" |
" |
" |
99 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q2 |
" |
" |
" |
|||||||
" |
" |
" |
100 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q 2 |
" |
" |
" |
|||||||
" |
tPHL |
" |
101 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q1 |
" |
40 |
" |
|||||||
" |
" |
" |
102 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q 1 |
" |
" |
" |
|||||||
" |
" |
" |
103 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q2 |
" |
" |
" |
|||||||
" |
" |
" |
104 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q 2 |
" |
" |
" |
|||||||
10 TC = 125°C |
FMAX |
(Fig. 7) 6/ |
105 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Q1 |
10 |
MHz |
||||||||
" |
" |
106 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Q 1 |
" |
" |
|||||||||
" |
" |
" |
107 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Q2 |
" |
" |
||||||||
" |
" |
" |
108 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Q 2 |
" |
" |
||||||||
" |
tPLH |
3003 (Fig 6) |
109 |
2.4 v |
OUT |
GND |
" |
A |
IN |
" |
Clr 1 to Q 1 |
5 |
39 |
ns |
|||||||
" |
tPLH |
" |
110 |
OUT |
" |
2.4 v |
A |
IN |
GND |
" |
Clr 2 to Q 2 |
" |
39 |
" |
|||||||
" |
tPHL |
" |
111 |
2.4 v |
OUT |
GND |
" |
A |
IN |
" |
Clr 1 to Q1 |
" |
50 |
" |
|||||||
" |
tPHL |
" |
112 |
OUT |
" |
2.4 v |
A |
IN |
GND |
" |
Clr 2 to Q2 |
" |
50 |
" |
|||||||
" |
tPLH |
3003 (Fig 7) |
113 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q1 |
5 |
39 |
ns |
|||||||
" |
" |
114 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q 1 |
" |
" |
" |
||||||||
" |
" |
" |
115 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q2 |
" |
" |
" |
|||||||
" |
" |
" |
116 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q 2 |
" |
" |
" |
|||||||
" |
tPHL |
" |
117 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q1 |
" |
50 |
" |
|||||||
" |
" |
" |
118 |
2.4 v |
OUT |
2.4 v |
" |
IN |
5.0 v |
" |
Clk 1 to Q 1 |
" |
" |
" |
|||||||
" |
" |
" |
119 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q2 |
" |
" |
" |
|||||||
" |
" |
" |
120 |
OUT |
" |
2.4 v |
IN |
5.0 v |
2.4 v |
" |
Clk 2 to Q 2 |
" |
" |
" |
|||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
See notes at end of device type 03.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business