TABLE III. Group A inspection for device type 01. 1/ - Continued.
Subgroup |
Symbol |
MIL- STD-883 method |
Case A, B, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Case C |
9 |
12 |
13 |
14 |
2 |
1 |
3 |
4 |
5 |
6 |
7 |
8 |
10 |
11 |
|||||||
Test No. |
K1 |
Clock |
Preset |
VCC |
Clear |
NC |
J1 |
J2 |
J3 |
Q |
GND |
Q |
K2 |
K3 |
Min |
Max |
Unit |
||||
7 2/ 4/ TC = 25°C |
91 |
B |
A |
A |
4.5 V |
A |
B |
B |
A |
A |
H |
GND |
L |
A |
A |
All output |
H or L As shown 3/ |
||||
92 |
B |
B |
A |
4.5 V |
A |
B |
B |
A |
A |
L |
GND |
H |
A |
A |
|||||||
8 2/ 4/ |
Same tests, terminal conditions and limits as for subgroup 7, except TC = 125 and -55°C. |
||||||||||||||||||||
9 TC = 25°C |
FMAX 5/ |
(Fig. 5) |
93 |
2.4 V |
IN |
5.0 V |
5.0 V |
5.0 V |
2.4 V |
2.4 V |
2.4 V |
GND |
OUT |
2.4 V |
2.4 V |
Q |
10 |
MHz |
|||
FMAX 5/ |
(Fig. 5) |
94 |
" |
IN |
5.0 V |
" |
5.0 V |
" |
" |
" |
OUT |
" |
" |
" |
Q |
10 |
MHz |
||||
" |
tPLH1 |
3003 (Fig. 4) |
95 |
" |
2.4 V |
J |
" |
IN |
" |
" |
" |
OUT |
" |
" |
" |
Clear to Q |
5 |
25 |
ns |
||
" |
tPLH1 |
96 |
" |
" |
IN |
" |
J |
" |
" |
" |
" |
OUT |
" |
" |
Preset to Q |
" |
25 |
" |
|||
" |
tPHL1 |
" |
97 |
" |
" |
J |
" |
IN |
" |
" |
" |
" |
OUT |
" |
" |
Clear to Q |
" |
40 |
" |
||
" |
tPHL1 |
" |
98 |
" |
" |
IN |
" |
J |
" |
" |
" |
OUT |
" |
" |
" |
Preset to Q |
" |
40 |
" |
||
" |
tPLH2 |
3003 (Fig 5 |
99 |
" |
IN |
5.0 V |
" |
5.0 V |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
30 |
ns |
||
" |
tPLH2 |
" |
100 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clock to Q |
" |
30 |
" |
||
" |
tPHL2 |
" |
101 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
40 |
" |
||
" |
tPHL2 |
" |
102 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clock to Q |
40 |
" |
|||
10 TC = 125°C |
FMAX 5/ |
(Fig 5) |
103 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Q |
10 |
MHz |
|||
FMAX 5/ |
(Fig 5) |
104 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Q |
10 |
MHz |
||||
" |
tPLH1 |
3003 (Fig. 4) |
105 |
" |
2.4 V |
J |
" |
IN |
" |
" |
" |
OUT |
" |
" |
" |
Clear to Q |
5 |
39 |
ns |
||
" |
tPLH1 |
" |
106 |
" |
" |
IN |
" |
J |
" |
" |
" |
" |
OUT |
" |
" |
Preset to Q |
" |
39 |
" |
||
" |
tPHL1 |
" |
107 |
" |
" |
J |
" |
IN |
" |
" |
" |
OUT |
" |
" |
Clear to Q |
" |
50 |
" |
|||
" |
tPHL1 |
" |
108 |
" |
" |
IN |
" |
J |
" |
" |
" |
OUT |
" |
" |
" |
Preset to Q |
" |
50 |
" |
||
" |
tPLH2 |
(Fig 5) |
109 |
" |
IN |
5.0 V |
" |
5.0 V |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
39 |
ns |
||
" |
tPLH2 |
" |
110 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clock to Q |
" |
39 |
" |
||
" |
tPHL2 |
" |
111 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
" |
Clock to Q |
" |
50 |
" |
||
" |
tPHL2 |
" |
112 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
" |
Clock to Q |
" |
50 |
" |
|||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
NOTES:
A = Normal clock pulse.
B = Momentary GND, then 4.5 V.
J = Input pulse tp = 100 ns, PRR = 1 MHz, VOL = 0 V, VOH = 4.5 V
*After clock pulse apply -12 mA to clock pin to insure Q is still in the low state (see figure 15).
1/ Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
2/ Input voltages shown are: A= 2.0 volts minimum and B = 0.8 volts maximum.
3/ Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double camparator; or (b) H � 1.5 V and L < 1.5 V when using a high speed checker single comparator.
4/ Tests shall be performed in sequence.
5/ FMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business