MIL-M-38510/11?C
TABLE IV. Group C end point electrical parameters. (TA = +25°C)
Device type |
Characteristic |
Symbol |
Delta limits 1/ |
Limits |
Units |
|
Min |
Max |
|||||
01, 02 |
Output voltage |
VOUT 2/ |
±50 mV |
4.?5 |
5.25 |
V |
Standby current drain |
ISCD |
±20 % |
-8.0 |
-0.5 |
mA |
|
03, 04, 05 |
Output voltage |
VOUT 2/ |
±10 mV |
1.20 |
1.30 |
V |
06 |
Output voltage |
VOUT 2/ |
±10 mV |
1.19 |
1.29 |
V |
03, 04, 05, 06 |
Adjust pin current |
IADJ 3/ |
±10 µA |
-100 |
-15 |
µA |
03, 04 |
Line regulation |
VRLINE |
±4 mV |
-9 |
9 |
mV |
05, 06 |
Line regulation |
VRLINE |
±2 mV |
-4 |
4 |
mV |
1/ Delta limits apply to the measured value (see delta limit definition in MIL-PRF-38535).
2/ Delta limits apply to test number 3 for all device types.
3/ Delta limits apply to test number 11 for all device types 03, 04, 05 and test number 12 for device type 06.
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Point's packaging activity within the Military Service or Defense Agency, or within the military service's system command. Packaging data retrieval is available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.
58
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business