MIL-M-38510/117C
Device table |
|||||||
Device type |
01 |
02 |
03 |
04 |
05 |
06 |
Notes |
VIN |
10 V |
10 V |
6.25 V |
6.25 V |
6.25 V |
6.25 V |
1 |
�VIN |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
1 |
RL |
1.25 kn |
1.25 kn |
120 n |
120 n |
120 n |
120 n |
|
tTHL = tTLH |
5.0 µs |
5.0 µs |
5.0 µs |
5.0 µs |
5.0 µs |
5.0 µs |
1 |
CL |
0.1 µF |
0.1 µF |
1.0 µF |
1.0 µF |
1.0 µF |
1.0 µF |
NOTES:
1. Measured at device input.
2. Pulse width tp1 = 25 µs: duty cycle = 3% (maximum).
3. Oscilloscope bandwidth = 5 MHz to 15 MHz.
4. The control pin connection is required for device types 01 and 02 only.
5. The input 25 n resistor and RL shall be type RER 70 or equivalent.
FIGURE 13. Line transient response test circuit.
37