MIL-M-38510/117C
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ -55°C � TA � +125°C see figure 9 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Output voltage |
VOUT |
VIN = 8 V |
IL = -5 mA, -1 A |
02 |
4.75 |
5.25 |
V |
VIN = 30 V |
IL = -5 mA, -100 mA |
4.75 |
5.25 |
||||
VIN = 38 V |
IL = -1 A |
28.5 |
31.5 |
||||
VIN = 10 V, TA = 150°C |
IL = -5 mA |
4.75 |
5.25 |
||||
Line regulation |
VRLINE |
8 V � VIN � 30 V |
IL = -100 mA |
02 |
-150 |
150 |
mV |
8 V � VIN � 25 V |
IL = -500 mA |
-50 |
50 |
||||
Load regulation |
VRLOAD |
VIN = 10 V |
-1 A � IL � -5 mA |
02 |
-100 |
100 |
mV |
VIN = 30 V |
-100 mA � IL � -5 mA |
-150 |
150 |
||||
Thermal regulation |
VRTH |
VIN = 15 V, TA = 25°C |
IL = -1 A |
02 |
-50 |
50 |
mV |
Standby current drain |
ISCD |
VIN = 10 V |
IL = -5 mA |
02 |
-7.0 |
-0.5 |
mA |
VIN = 30 V |
IL = -5 mA |
-8.0 |
-0.5 |
||||
Standby current drain change versus line voltage |
�ISCD (LINE) |
8 V � VIN � 30 V |
IL = -5 mA |
02 |
-1.0 |
1.0 |
mA |
Standby current drain change versus load current |
�ISCD (LOAD) |
VIN = 10 V |
-1 A � IL � -5 mA |
02 |
-0.5 |
0.5 |
mA |
Control pin current |
ICTL |
VIN = 10 V, TA = 25°C |
IL = -500 mA |
02 |
-5.0 |
-0.01 |
µA |
VIN = 10 V, -55°C � TA � 125°C |
IL = -500 mA |
-8.0 |
-0.01 |
See footnotes at end of table.