MIL-M-38510/11?C
Device table |
||||||
Device types |
01 |
02 |
03 |
04 |
05 |
06 |
vIN |
10 v |
10 v |
6.25 v |
6.25 v |
6.25 v |
6.25 v |
RL |
40.2 n |
14.3 n |
10 n |
2.5 n |
2.5 n |
2.5 n |
Ci |
0.33 µF |
0.33 µF |
1.0 µF |
1.0 µF |
1.0 µF |
1.0 µF |
CL |
0.1 µF |
0.1 µF |
1.0 µF |
1.0 µF |
1.0 µF |
1.0 µF |
NOTES:
1. ei = 1 vrms at f = 2400 Hz (measured at the input terminals of the DUT).
Ripple rejection = 20 log (eirms / eorms).
2. The control pin connection is required for device types 01 and 02 only.
3. The input 50 n resistor and RL shall be type RER ?0 or equivalent.
4. The meter for ei and eo shall have a minimum bandwidth from 10 Hz to 10 kHz for devices 01 - 05 and
300 Hz to 10 kHz for device type 06 shall measure true rms voltages.
FIGURE 11. Ripple rejection test circuit.
35
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business