MIL-M-38510I115B
TABLE III. Group A inspection for all device type 06 - Continued.
Subgroup |
Symbol |
Test no. |
Conditions see figure 5, unless otherwise specified |
Limits |
Unit |
Notes |
||
Min |
Max |
|||||||
Input voltage |
Load current |
|||||||
5 TA = 125°C |
VIN I VOUT |
58 |
VIN = -17 V, ei = 1 V rms at f = 2400 Hz |
IL = 350 mA |
50 |
dB |
See figure 7, meter BW 10 Hz to 10 kHz |
|
6 TA = -55°C |
VIN I VOUT |
59 |
VIN = -17 V, ei = 1 V rms at f = 2400 Hz |
IL = 350 mA |
50 |
dB |
See figure 7, meter BW 10 Hz to 10 kHz |
|
7 TA = 25°C |
VNO |
60 |
VIN = -17 V |
IL = 0.1 A |
600 |
∝V rms |
See figure 8 |
|
VOUT I VIN |
61 |
VIN = -17 V, VPULSE = -3.0 V |
IL = 5 mA |
30 |
mVIV |
See figure 9 |
||
VOUT I IL |
62 |
VIN = -17 V |
IL = 100 mA IL = 400 mA |
2.5 |
mVImA |
See figure 10 |
55