MIL-M-38510/115B
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ 3/ -55°C = TA = +125°C see figure 5 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Standby current drain change (versus line voltage) |
ISCD (line) |
-30 V = VIN = -8 V |
IL = 5 mA |
05 |
-1.0 |
1.0 |
mA |
Standby current drain change (versus load current) |
ISCD (load) |
VIN = -10 V |
5 mA = IL = 1.0 A |
05 |
-0.5 |
0.5 |
mA |
Output short circuit current |
IOS |
VIN = -25 V |
05 |
0.00 |
3.50 |
A |
|
VIN = -30 V |
0.00 |
2.00 |
|||||
Peak output current |
IPK |
VIN = -8 V, forced VOUT = 0.48 V, see figure 6 |
05 |
1.0 |
4.50 |
A |
|
Ripple rejection |
VIN / VOUT |
VIN = -10 V, ei = 1 Vrms, at f = 2400 Hz |
IL = 350 mA, meter BW 10 Hz to 10 kHz, see figure 7 |
05 |
45 |
dB |
|
Thermal regulation |
VRTH |
VIN = -15 V |
IL = 1.0 A, TA = 25°C |
05 |
-50 |
50 |
mV |
Output noise voltage |
VNO |
VIN = -10 V |
IL = 0.1 A |
05 |
250 |
∝Vrms |
|
Voltage start-up |
VSTART |
VIN = -20 V |
RL = 5 ν, see figure 11 |
05 |
-5.25 |
-4.75 |
V |
Line transient response |
VOUT / VIN |
VIN = -10 V, VPULSE = -3.0 V, see figure 9 |
IL = 5 mA, TA = 25°C |
05 |
30 |
mV/V |
|
Load transient response |
VOUT / IL |
VIN = -10 V, see figure 10 |
IL = 100 mA, IL = 400 mA, TA = 25°C |
05 |
2.5 |
mV/mA |