MIL-M-38510/1158
TA8LE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ 3/ -55°C = TA = +125°C see figure 5 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Load transient response |
VOUT / IL |
VIN = -20 V, see figure 10 |
IL = 100 mA, IL = 400 mA, TA = 25°C |
07 |
2.5 |
mV/mA |
|
Output voltage |
VOUT |
VIN = -28 V |
IL = 5 mA, 1.0 A |
08 |
-25.20 |
-22.80 |
V |
VIN = -38 V |
IL = 5 mA, 1.0 A |
-25.20 |
-22.80 |
||||
VIN = -40 V |
IL = 5 mA, 0.1 A |
-25.20 |
-22.80 |
||||
VIN = -30 V |
IL = 5 mA, TA = 150°C |
-25.44 |
-22.56 |
||||
Line regulation |
VRLINE |
-40 V = VIN = -28 V |
IL = 0.1 A |
08 |
-720 |
720 |
mV |
-38 V = VIN = -28 V |
IL = 0.5 A |
-240 |
240 |
||||
Load regulation |
VRLOAD |
VIN = -30 V |
5 mA = IL = 1.0 A |
08 |
-480 |
480 |
mV |
VIN = -40 V |
5 mA = IL = 0.1 A |
-720 |
720 |
||||
Standby current drain |
ISCD |
VIN = -30 V |
IL = 5 mA |
08 |
0.5 |
4.0 |
mA |
VIN = -40 V |
IL = 5 mA |
0.5 |
4.0 |
||||
Standby current drain change (versus line voltage) |
ISCD (line) |
-40 V = VIN = -28 V |
IL = 5 mA |
08 |
-1.0 |
1.0 |
mA |
Standby current drain change (versus load current) |
ISCD (load) |
VIN = -30 V |
5 mA = IL = 1.0 A |
08 |
-0.5 |
0.5 |
mA |
Output short circuit current |
IOS |
VIN = -30 V |
08 |
0.00 |
3.00 |
A |
|
VIN = -40 V |
0.00 |
2.00 |
See footnotes at end of table.
16
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business