MIL-M-38510/1158
TA8LE I. Electrical performance characteristics.
Test |
Symbol |
Conditions 1/ 2/ -55°C = TA = +125°C see figure 5 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Output voltage |
VOUT |
VIN = -8 V |
IL = 5 mA, 0.5 A |
01 |
-5.25 |
-4.75 |
V |
VIN = -20 V |
IL = 5 mA, 0.5 A |
-5.25 |
-4.75 |
||||
VIN = -30 V |
IL = 5 mA, IL = 50 mA |
-5.25 |
-4.75 |
||||
VIN = -10 V |
IL = 5 mA, TA = 150°C |
-5.30 |
-4.70 |
||||
Line regulation |
VRLINE |
-30 V = VIN = -8 V |
IL = 50 mA |
01 |
-150 |
150 |
mV |
-25 V = VIN = -8 V |
IL = 350 mA |
-50 |
50 |
||||
Load regulation |
VRLOAD |
VIN = -10 V |
5 mA = IL = 500 mA |
01 |
-100 |
100 |
mV |
VIN = -30 V |
5 mA = IL = 50 mA |
-150 |
150 |
||||
Standby current drain |
ISCD |
VIN = -10 V |
IL = 5 mA |
01 |
0.5 |
3.0 |
mA |
VIN = -30 V |
IL = 5 mA |
0.5 |
4.0 |
||||
Standby current drain change (versus line voltage) |
ISCD (line) |
-30 V = VIN = -8 V |
IL = 5 mA |
01 |
-1.0 |
1.0 |
mA |
Standby current drain change (versus load current) |
ISCD (load) |
VIN = -10 V |
5 mA = IL = 500 mA |
01 |
-0.5 |
0.5 |
mA |
Output short circuit current |
IOS |
VIN = -25 V |
01 |
0.00 |
1.50 |
A |
|
VIN = -30 V |
0.00 |
1.00 |
|||||
Peak output current |
IPK |
VIN = -8 V, forced VOUT = 0.48 V, see figure 6 |
01 |
0.5 |
2.0 |
A |
See footnotes at end of table.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business