MIL-M-38510/1158
TA8LE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ 3/ -55°C = TA = +125°C see figure 5 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Output voltage |
VOUT |
VIN = -15 V |
IL = 5 mA, 1.0 A |
06 |
-12.60 |
-11.40 |
V |
VIN = -27 V |
IL = 5 mA, 1.0 A |
-12.60 |
-11.40 |
||||
VIN = -35 V |
IL = 5 mA, 0.1 A |
-12.60 |
-11.40 |
||||
VIN = -17 V |
IL = 5 mA, TA = 150°C |
-12.72 |
-11.40 |
||||
Line regulation |
VRLINE |
-35 V = VIN = -15 V |
IL = 0.1 A |
06 |
-360 |
360 |
mV |
-32 V = VIN = -15 V |
IL = 0.5 A |
-120 |
120 |
||||
Load regulation |
VRLOAD |
VIN = -17 V |
5 mA = IL = 1.0 A |
06 |
-240 |
240 |
mV |
VIN = -35 V |
5 mA = IL = 0.1 A |
-360 |
360 |
||||
Standby current drain |
ISCD |
VIN = -17 V |
IL = 5 mA |
06 |
0.5 |
3.0 |
mA |
VIN = -35 V |
IL = 5 mA |
0.5 |
4.0 |
||||
Standby current drain change (versus line voltage) |
ISCD (line) |
-32 V = VIN = -15 V |
IL = 5 mA |
06 |
-1.0 |
1.0 |
mA |
Standby current drain change (versus load current) |
ISCD (load) |
VIN = -17 V |
5 mA = IL = 1.0 A |
06 |
-0.5 |
0.5 |
mA |
Output short circuit current |
IOS |
VIN = -32 V |
06 |
0.00 |
3.50 |
A |
|
VIN = -35 V |
0.00 |
2.00 |
|||||
Peak output current |
IPK |
VIN = -15 V, forced VOUT = 1.13 V, see figure 6 |
06 |
1.0 |
4. 0 |
A |
See footnotes at end of table.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business