MIL-M-38510/115B
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ 3/ -55°C = TA = +125°C see figure 5 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Standby current drain |
ISCD |
VIN = -20 V |
IL = 5 mA |
07 |
0.5 |
3.0 |
mA |
VIN = -35 V |
IL = 5 mA |
0.5 |
4.0 |
||||
Standby current drain change (versus line voltage) |
ISCD (line) |
-35 V = VIN = -18.5 V |
IL = 5 mA |
07 |
-1.0 |
1.0 |
mA |
Standby current drain change (versus load current) |
ISCD (load) |
VIN = -20 V |
5 mA = IL = 1.0 A |
07 |
-0.5 |
0.5 |
mA |
Output short circuit current |
IOS |
VIN = -20 V |
07 |
0.00 |
3.50 |
A |
|
VIN = -35 V |
0.00 |
2.00 |
|||||
Peak output current |
IPK |
VIN = -18.5 V, forced VOUT = 1.43 V, see figure 6 |
07 |
1.0 |
4. 0 |
A |
|
Ripple rejection |
VIN / VOUT |
VIN = -20 V, ei = 1 Vrms, at f = 2400 Hz |
IL = 350 mA, meter BW 10 Hz to 10 kHz, see figure 7 |
07 |
50 |
dB |
|
Output noise voltage |
VNO |
VIN = -20 V, see figure 8 |
IL = 0.1 A |
07 |
700 |
∝Vrms |
|
Thermal regulation |
VRTH |
VIN = -25 V |
IL = 1.0 A, TA = 25°C |
07 |
-150 |
150 |
mV |
Voltage start-up |
VSTART |
VIN = -30 V |
RL = 15 ν, see figure 11 |
07 |
-15.75 |
-14.25 |
V |
Line transient response |
VOUT / VIN |
VIN = -20 V, VPULSE = -3.0 V, see figure 9 |
IL = 5 mA, TA = 25°C |
07 |
30 |
mV/V |
See footnotes at end of table.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.