MIL-M-38510/1158
Device types |
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
VL |
-10 V |
-17 V |
-20 V |
-30 V |
-10 V |
-17 V |
-20 V |
-30 V |
RL |
100 ν |
243 ν |
301 ν |
487 ν |
49.9 ν |
121 ν |
150 ν |
243 ν |
NOTES:
1. The pulse characteristics shall be established under load while the DUT is operating. tTLH = tTHL = 1.0 μs
tp2 = 25 μs at 3% duty cycle.
VPULSE = -0.2 V for device types 01, 02, 03, and 04. VPULSE = -0.4 V for device types 05, 06, 07, and 08.
2. VOUT = 500 mV maximum for device types 01 - 04.
VOUT = 1000 mV maximum for device types 05 - 08.
(These values guarantee the specified limits for load transient response).
3. Oscilloscope minimum bandwidth shall be 5 MHz.
4. Load resistor RL is type RER 70 or equivalent.
FIGURE 10. Load transient response test circuit.
30
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business