MIL-M-38510/115B
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ 3/ -55°C = TA = +125°C see figure 5 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Peak output current |
IPK |
VIN = -28 V, forced VOUT = 2.28 V, see figure 6 |
08 |
1.0 |
4. 0 |
A |
|
Ripple rejection |
VIN / VOUT |
VIN = -30 V, ei = 1 Vrms, at f = 2400 Hz |
IL = 350 mA, meter BW 10 Hz to 10 kHz, see figure 7 |
08 |
50 |
dB |
|
Output noise voltage |
VNO |
VIN = -30 V, see figure 8 |
IL = 0.1 A, TA = +25°C |
08 |
1000 |
∝Vrms |
|
Thermal regulation |
VRTH |
VIN = -34 V |
IL = 1.0 A, TA = 25°C |
08 |
-240 |
240 |
mV |
Voltage start-up |
VSTART |
VIN = -38 V |
RL = 24 ν, see figure 11 |
08 |
-25.20 |
-22.80 |
V |
Line transient response |
VOUT / VIN |
VIN = -30 V, VPULSE = -3.0 V, see figure 9 |
IL = 5 mA, TA = 25°C |
08 |
30 |
mV/V |
|
Load transient response |
VOUT / IL |
VIN = -30 V, see figure 10 |
IL = 100 mA, IL = 400 mA, TA = 25°C |
08 |
2.5 |
mV/mA |
1/ All tests performed at TA = 125°C may at the manufacturer's option, be performed at TA = 150°C.
Specifications for TA = 125°C shall then apply at TA = 150°C.
2/ In any test sequence in which IOS and IPK are tested, they shall be followed by the voltage start up test.
3/ Recovery of output voltage after the output short circuit test is not guaranteed.