MIL-M-38510/507B
TABLE VI. Product term addresses.
Product term |
Pin name |
|||
I7 |
I8 |
I9 |
I10 |
|
0 |
VILP |
VILP |
VILP |
VILP |
1 |
VIHP |
VILP |
VILP |
VILP |
2 |
VILP |
VIHP |
VILP |
VILP |
3 |
VIHP |
VIHP |
VILP |
VILP |
4 |
VILP |
VILP |
VIHP |
VILP |
5 |
VIHP |
VILP |
VIHP |
VILP |
6 |
VILP |
VIHP |
VIHP |
VILP |
7 |
VIHP |
VIHP |
VIHP |
VILP |
8 |
VILP |
VILP |
VILP |
VIHP |
9 |
VIHP |
VILP |
VILP |
VIHP |
10 |
VILP |
VIHP |
VILP |
VIHP |
11 |
VIHP |
VIHP |
VILP |
VIHP |
12 |
VILP |
VILP |
VIHP |
VIHP |
13 |
VIHP |
VILP |
VIHP |
VIHP |
14 |
VILP |
VIHP |
VIHP |
VIHP |
15 |
VIHP |
VIHP |
VIHP |
VIHP |
TABLE VII. Architecture bit addressing.
Architecture bit |
I8 |
I9 |
Output polarity (C0) |
VILP |
VILP |
Register / Nonregister output (C1) |
VIHP |
VILP |
TABLE VIII. Phantom input term addresses.
Phantom input term |
I3 |
I4 |
P0 |
VILP |
VILP |
P1 |
VIHP |
VILP |
P2 |
VILP |
VIHP |
P3 |
VIHP |
VIHP |
TABLE IX. Delta limits at ± 25 °C.
Parameter 1/ |
Device types |
All |
|
ICC |
± 2 mA |
IOZH |
± 10% of specified value |
IOZH |
± 10% of specified value |
1/ The above parameter shall be
recorded before and after the required burn-in and life tests to determine the delta (∆).