TABLE lll. Group A inspection for device type 07 - Continued.
1/ Case X and 2 pins not referenced are NC.
2/
- - - 2.5 V minumum/5.5 V maximum
0 V
3/ llL limits in mA are as follows:
llL1 |
Min/Max limits for CKT |
||||||
A |
B |
C |
D |
E |
F |
G |
|
-.075/-.250 |
-.100/-.340 |
-.075/-.250 |
-.075/-.250 |
-.120/-.360 |
-.160/-.400 |
-.075/-.250 |
llL2 |
Min/Max limits for CKT |
||||||
A |
B |
C |
D |
E |
F |
G |
|
-.085/-.270 for test 35 -.135/-.400 for test 36 |
-.150/-.420 |
-.125/-.275 for test 35 -.160/-.400 for test 36 |
-.120/-.400 for test 35 -.120/-.360 for test 36 |
-.120/-.400 |
-.105/-.380 for test 35 -.160/-.400 for test 36 |
-.075/-.250 for test 35 -.120/-.360 for test 36 |
4/
2.5 V minumum/5.5 V maximum
0 V
5/ lnput voltages shown are A = 2.0 volts minimum and B = 0.7 volts maximum.
6/ Tests shall be performed in sequence, attributes data only.
7/ Output voltages shall be H � 1.5 V and L < 1.5 V.
8/ fMAX minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business