MIL-M-3851O/3O1F
DEVICE TYPES O3 AND 1O
INPUTS |
OUTPUTS |
|||||
PRESET |
CLEAR |
CLOCK |
J |
K |
Q |
Q |
L |
H |
x |
x |
x |
H |
L |
H |
L |
x |
x |
x |
L |
H |
L |
L |
x |
x |
x |
H* |
H* |
H |
H |
↓ |
L |
L |
QO |
Q O |
H |
H |
↓ |
H |
L |
H |
L |
H |
H |
↓ |
L |
H |
L |
H |
H |
H |
↓ |
H |
H |
TOGGLE |
|
H |
H |
H |
x |
x |
QO |
Q O |
H = high level (steady state) L = low level (steady state)
x = irrelevant
↓ = transition from high to low level
QO = the level of Q before the indicated steady state input conditions were established.
TOGGLE: Each output changes to the complement of its previous level on each ↓ clock transition.
* This configuration is nonstable; that is, it will not persist when preset and clear inputs return to their inactive (high) level.
DEVICE TYPE O4
INPUTS |
OUTPUTS |
||||
PRESET |
CLOCK |
J |
K |
Q |
Q |
L |
H |
x |
x |
H |
L |
H |
↓ |
L |
L |
QO |
Q O |
H |
↓ |
H |
L |
H |
L |
H |
↓ |
L |
H |
L |
H |
H |
↓ |
H |
H |
TOGGLE |
|
H |
H |
x |
x |
QO |
Q O |
H = high level (steady state) L = low level (steady state)
x = irrelevant
↓ = transition from high to low level
QO = the level of Q before the indicated input conditions were established.
TOGGLE: Each output changes to the complement of its previous level on each ↓ clock transition.
FIGURE 3. Truth tables - Continued.
16
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business