TABLE lll. Group A inspection for device type 05 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V, low s 0.7 V, or open).
1/ Case X and 2 pins not referenced are NC.
2/ - - - 2.5 V minumum/5.5 V maximum
0 V
3/ - - - 2.5 V minumum/5.5 V maximum
0 V
4/ llL limits in mA are as follows:
llL4 |
Min/Max limits for CKT |
||||
A |
B |
C |
D |
E |
|
-.200/-.800 |
-.060/-.700 |
-.290/-.650 |
-.120/-.720 |
-.320/-.800 |
llL6 |
Min/Max limits for CKT |
||||
A |
B |
C |
D |
E |
|
-.300/-1.000 |
-.120/-1.000 |
-.300/-1.120 |
-.240/-1.440 |
-.560/-1.520 |
llL7 |
Min/Max limits for CKT |
||||
A |
B |
C |
D |
E |
|
-.450/-1.300 |
-.120/-1.000 |
-.580/-1.300 |
-.120/-1.500 |
-.640/-1.600 |
5/ lnput voltages shown are A = 2.0 volts minimum and B = 0.7 volt maximum.
6/ Tests shall be performed in sequence, attributes data only.
7/ Output voltages shall be H � 1.5 V and L < 1.5 V.
8/ fMAX minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.