MIL-M-38510/289A
The example shows Write pulse setup time defined as tWLEH-time from Write Enable to low to Chip Enable High.
c. Timing limits. The table of timing values shows either a minimum or a maximum limit for each parameter.
Input requirements are specified from the external system point of view. Thus, address set up time is shown as a minimum since the system must supply at least that much time (even though most devices
do not require it). On the other hand, responses from the memory are specified from the device point of
view. Thus, the access time is shown as a maximum since the device never provides data later than that time.
d. Waveforms:
26
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business