MIL-M-38510/289A
3.4 Lead material and finish. The lead material and finish shall be in accordance with MIL-PRF-38535 (see 6.6).
3.5 Electrical performance characteristics. Unless otherwise specified, the electrical performance characteristics are as specified in table I, and apply over the full recommended case operating temperature range.
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table III.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group number 41 (see MIL-PRF-38535, appendix A).
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not effect the form, fit, or function as described herein.
4.2 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
4.3 Screening. Screening shall be in accordance with MIL-PRF-38535, and shall be conducted prior to qualification, and conformance inspection. The following additional criteria shall apply:
a. A cell bit stress test may be used for the special electrical screen test of method 5004. The cell bit
stress test shall be conducted per table III test number 42 for device types 01, 03, and test number 54 for device types 02 and 04. The functional test shall be the checkerboard / checkboard algorithm of the appendix. This test shall be performed once at the first high temperature (125°C) functional test only.
b. The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under document control by the device manufacturer's Technology Review Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1015 of MIL-STD-883.
c. Interim and final electrical tests shall be as specified in table II, except interim electrical tests prior to burn- in are optional at the discretion of the manufacturer.
d. Additional screening for space level product shall be as specified in MIL-PRF-38535.
4