TABLE III. Group A inspection for device type 06 - Continued. 1/
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
|||||
Test no. |
Clock 1 |
Clear 1 |
K1 |
vCC |
Clock 2 |
Clear 2 |
J2 |
Q2 |
Q2 |
K2 |
GND |
Q1 |
Q1 |
J1 |
|||||||
1 TC=+25°C |
IOS |
3011 |
45** 46 47** 48 |
2.4 v 2.4 v |
2.4 v GND |
2.4 v 2.4 v |
5.5 v " " " |
2.4 v 2.4 v |
2.4 v GND |
2.4 v 2.4 v |
GND GND |
GND |
2.4 v 2.4 v |
GND " " " |
GND |
GND GND |
2.4 v 24.v |
Q1 Q1 Q2 Q2 |
-40 " " " |
-100 " " " |
mA " " " |
ICC |
3005 |
49 |
GND |
GND |
GND |
" |
GND |
GND |
GND |
GND |
" |
GND |
vCC |
76 |
" |
||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC=+125°C and vIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC=-55°C and vIC tests are omitted. |
||||||||||||||||||||
7 TC=+25°C 3/ 4/ |
50 51 52 53 54 55 56 57 58 59 60 61 62 63 |
A A B A B A A B A B A B A B |
B A " " " " B B A " " " " " |
B " " " " " " " A A B B A A |
4.5 v " " " " " " " " " " " " " |
A A B A B A A B A B A B A B |
B A " " " " B B A " " " " " |
B " " A " " " " " " B B A A |
H " " " L L H " " L " " " H |
L " " " H H L " " H " " " L |
B " " " " " " " A A B B A A |
GND " " " " " " " " " " " " " |
L " " " H H L " " H " " " L |
H " " " L L H " " L " " " H |
B " " A " " " " " " B B A A |
All outputs " " " " " " " " " " " " |
H or L as shown 5/ " " " " " " " " " " " " |
||||
8 3/ 4/ |
Same tests, terminal conditions, and limits as for subgroup 7, except TC= +125°C and -55°C. |
||||||||||||||||||||
9 TC=+25°C |
fMAX 6/ |
(Fig. 15) |
64 65 66 67 |
IN IN |
5.0 v 5.0 v |
2.4 v 2.4 v |
5.0 v " " " |
IN IN |
5.0 v 5.0 v |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
GND " " " |
OUT |
OUT |
2.4 v 2.4 v |
Q1 Q1 Q2 Q2 |
36 " " " |
MHz " " " |
|
tPLH1 |
3003 (Fig. 14) |
68 69 |
G |
IN |
2.4 v |
" " |
B |
IN |
2.4 v |
OUT |
2.4 v |
" " |
OUT |
2.4 v |
Clear 1 to Q Clear 2 to Q |
2 " |
15 15 |
ns " |
|||
tPHL1 |
70 71 72 73 |
F G |
IN IN |
2.4 v 2.4 v |
" " " " |
G G |
IN IN |
2.4 v 2.4 v |
OUT OUT |
2.4 v 2.4 v |
" " " " |
OUT OUT |
2.4 v 2.4 v |
Clear 1 to Q Clock 2 to Q Clock 1 to Q Clear 2 to Q |
" " " " |
38 38 23 23 |
" " " " |
||||
tPLH2 |
3003 (Fig. 15) |
74 75 76 77 |
IN IN |
2.4 v P |
" " " " |
IN IN |
IN 2.4 v |
OUT |
OUT |
2.4 v P |
" " " " |
OUT |
OUT |
N 2.4 v |
Clock 1 to Q Clock 1 to Q Clock 2 to Q Clock 2 to Q |
" " " " |
18 " " " |
" " " " |
|||
tPHL2 |
78 79 80 81 |
IN IN |
R 2.4 v |
" " " " |
IN IN |
2.4 v S |
OUT |
OUT |
R 2.4 v |
" " " " |
OUT |
OUT |
2.4 v S |
Clock 1 to Q Clock 1 to Q Clock 2 to Q Clock 2 to Q |
" " " " |
23 " " " |
" " " " |
See footnotes at end of device type 06.