TABLE III. Group A inspection for device type 04 - Continued. 11
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases E,F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Test no. |
Clock 1 |
Preset 1 |
Clear 1 |
J1 |
vCC |
Clock 2 |
Preset 2 |
Clear 2 |
J2 |
Q2 |
Q2 |
K2 |
GND |
Q1 |
Q1 |
K1 |
Min |
Max |
|||||
1 TC=+25°C |
IOS |
3011 |
59** 60 61** 62 |
2.4 v 2.4 v |
GND 4.5 v |
4.5 v GND |
2.4 v 2.4 v |
5.5 v " " " |
2.4 v 2.4 v |
GND 4.5 v |
4.5 v GND |
2.4 v 2.4 v |
GND |
GND |
2.4 v 2.4 v |
GND " " " |
GND |
GND |
2.4 v 2.4 v |
Q1 Q1 Q2 Q2 |
-40 " " " |
-100 " " " |
mA " " " |
ICC |
3005 |
63 64 |
GND GND |
4.5 v GND |
GND 4.5 v |
GND GND |
" " |
GND GND |
4.5 v GND |
GND 4.5 v |
GND GND |
GND GND |
" " |
GND GND |
vCC vCC |
50 50 |
" " |
||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C and vIC tests are omitted. |
||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and vIC tests are omitted. |
||||||||||||||||||||||
7 TC=+25°C 21 31 |
65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 |
A " " B A B B A B B A B B A B |
B B A " " " " " " " " " " " " |
B A B A " " " " " " " " " " " |
B " " " " " A " " B " " A " " |
4.5 v " " " " " " " " " " " " " " |
A " " B A B B A B B A B B A B |
B B A " " " " " " " " " " " " |
B A B A " " " " " " " " " " " |
B " " " " " A " " B " " A " *A |
H L H " " " " " L " " " " " H |
H H L " " " " " H " " " " " L |
B " " " " " A " " B " " A " " |
GND " " " " " " " " " " " " " " |
H L H " " " " " L " " " " " H |
H H L " " " " " H " " " " " L |
B " " " " " A " " B " " A " " |
All outputs " " " " " " " " " " " " " |
H or L as shown 41 " " " " " " " " " " " " " |
||||
8 21 31 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC= +125°C and -55°C. |
||||||||||||||||||||||
9 TC=+25°C |
fMAX 51 |
(Fig. 11) |
80 81 82 83 |
IN IN |
5.0 v 5.0 v |
5.0 v 5.0 v |
2.4 v 2.4 v |
5.0 v " " " |
IN IN |
5.0 v 5.0 v |
5.0 v 5.0 v |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
GND " " " |
OUT |
OUT |
2.4 v 2.4 v |
Q1 Q1 Q2 Q2 |
25 " " " |
MHz " " " |
|
tPLH1 |
3003 (Fig. 10) |
84 85 86 87 |
2.4 v 2.4 v |
IN |
IN |
2.4 v 2.4 v |
" " " " |
2.4 v 2.4 v |
IN |
IN |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
" " " " |
OUT |
OUT |
2.4 v 2.4 v |
Clear 1 to Q1 Preset 1 to Q1 Clear 2 to Q2 Preset 2 to Q2 |
2 " " " |
16 " " " |
ns " " " |
|
tPHL1 |
88 89 90 91 |
2.4 v 2.4 v |
IN |
IN |
2.4 v 2.4 v |
" " " " |
2.4 v 2.4 v |
IN |
IN |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
" " " " |
OUT |
OUT |
2.4 v 2.4 v |
Clear 1 to Q1 Preset 1 to Q1 Clear 2 to Q2 Preset 2 to Q2 |
" " " " |
27 " " " |
" " " " |
||
tPLH2 |
3003 (Fig. 11) |
92 93 94 95 |
IN IN |
5.0 v 5.0 v |
5.0 v 5.0 v |
2.4 v 2.4 v |
" " " " |
IN IN |
5.0 v 5.0 v |
5.0 v 5.0 v |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
" " " " |
OUT |
OUT |
2.4 v 2.4 v |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
" " " " |
24 " " " |
" " " " |
|
tPHL2 |
96 97 98 99 |
IN IN |
5.0 v 5.0 v |
5.0 v 5.0 v |
2.4 v 2.4 v |
" " " " |
IN IN |
5.0 v 5.0 v |
5.0 v 5.0 v |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
" " " " |
OUT |
OUT |
2.4 v 2.4 v |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
" " " " |
30 " " " |
" " " " |
See footnotes at end of device 04.